SvBackCover.jpg (30014 bytes)IndexMechanism2.jpg (30654 bytes)I work on first edition 214's only. If need be, I will help you to verify that your Accutron is a caliber 214 before you send it.

The 214 is set from the rear of the case by lifting a spring loaded "C" shaped lever. Also on the rear of the case is a slotted hatch cover which unscrews to access the battery. If your Accutron does not have these features it is not a 214. Click on the thumbnail image (left) to see a larger photo.

 Click on the thumbnails for larger images and then use your "back" button to return. 

 THE REPAIR PROCESS: 

WhiteDiaFront.jpg (30184 bytes)

     The process begins with removal of rust and/or corrosion (if any), and ultrasonic cleaning to remove caked on debris.

 

 


ccrear.jpg (30096 bytes)   The back cover is dis-assembled, rust and/or corrosion (if any) is removed, and the parts are ultrasonically cleaned. A new gasket is installed in the battery hatch, and the cover is re-assembled.


 


 The movement is taken apart. All metal parts are ultrasonically cleaned. The movement is then re-assembled lubricated, and adjusted.  Finally, the dial and hands are installed on the movement. The assembly is then put back into its case, a new gasket is installed, and the cover is closed. The watch is then observed for approximately 2 weeks, during which time, fine adjustments can be made to the movement.
 

 CAUTION:  If you found an old Accutron in a drawer and put a battery in it, you may be quite pleased to find that it runs, but may I suggest that you remove the battery immediately, and have the watch serviced before it self destructs. For an explanation please visit the  Q & A Page 

 Is your 214 running way too fast?  See the information at:  http://www.accutron214.com/AccutronBattery.htm 

 BASIC 214 (non hacking) REPAIR / RESTORATION PRICE LIST 
Prices do not include replacements for damaged or missing  parts.
 FULLY INSURED - 1 YEAR GUARANTY 

 
 *REQUIRED SERVICE: $150.00 plus parts
Cleaning, lubrication, and adjustment of the movement to work correctly with a readily available 1.5V battery
Disassembly and cleaning of the case. (bezel, back cover, battery hatch, setting stem, and threaded lock ring)
Installation of replacement parts (if any)
Crystal polish (restores transparency and shine, does not remove scratches)
New 387S Energizer battery
New gaskets
New stainless steel spring pins for your band or bracelet
One year guarantee
(parts and labor)
*Regulator diode may be required at additional cost 

 DEPOSIT - ALL MODELS: 
A deposit of $50.00 is required. The deposit will cover the cost of inspection and return shipping should you decide not to proceed with the repair & restoration. The deposit will be applied to the total if repair is authorized.
 


 OPTIONAL SERVICES 

 COIL MODIFICATION: 
Install regulator diode to reduce battery voltage to 1.3 volts: $50.  Optional for most 214's) (required on over-active movements

 CRYSTALS: 
Sand, buff, & polish old crystal: $20.00 (removes all but the deepest scratches)
New Generic Crystal; $20
New-Old-Stock Crystal; $45.00 and up

 


 RESTORATION SERVICES 

 STAINLESS STEEL BEZELS: 
Buff stainless steel bezel: $95.00

 GOLD & GOLD FILLED BEZELS: 
Gently buffed & polished: $75.

 REAR COVERS: ** CoverAfter.jpg (30031 bytes)BeforeAfterRear.jpg (30016 bytes)
Restore straight & circular graining on rear cover, setting stem, & battery hatch: $125.00    

 THREADED LOCK RINGS: 
Buff stainless lock ring: $35.00

 214 DIALS: 
Remove old luminous, clean dial and apply fresh high-glow luminous paint: $35.00

 LUMINOUS HANDS: 
Rust Free: Clean, and apply fresh high-glow luminous paint: $75.00
Rusted: Clean, clear coat, and apply fresh luminous paint: $95.00
 

 METAL BRACELETS: 
Ultrasonic cleaning: $10.00

 PLEASE NOTE:  Because each restoration project is unique, firm quotes can only be given after careful inspection.


 *  Ultra-bright, long lasting, long glowing Strontium Aluminate crystals.
 **  Same as original factory finish. Removes or hides all but the deepest scratches.

Accutron 214 Repair/Restoration Appointment Request 

 PRIVACY NOTICE:  The information you send on this form will automatically create invoices and return shipping labels. No information will be made available to anyone else for any purpose whatsoever.

I work on the first edition 214 caliber Accutron only. Please compare your watch's back cover with the photo at rightIyour Accutrons' back cover is similar it is a 214.

             Please provide the following information:
                                    
I have compared my watches back cover to the photo and it is a 214.
                                    
I have compared my watches back cover to the photo and it is not similar.                                   

Name
Street Address
Address (cont.)
City
State/Province
Zip/Postal Code
Country  
Home Phone
E-mail  
                Comments     

The best way to contact me is by e-mail. Please be advised that if you access my voice-mail and leave an e-mail address I will try to reply promptly but if you don't hear from me within one day it's probably because I didn't get your correct e-mail address and my message was returned as undeliverable. Due to the many incoming calls that I receive from people seeking information about their watches, I regret that I cannot return phone calls so please e-mail me by clicking the link below.

 If you phone please spell out your e-mail address slowly, enunciate clearly, and indicate whether there are spaces
 or capital  letters.

 Questions? Send eMail

Copyright  2002 by Martin Marcus. All rights reserved.
These pages may not be copied without written consent
.


WORK SPACES

 Click on the thumbnails for a larger image, then use your back button to return 

Sink2.jpg (30113 bytes)     newshop4.jpg (30104 bytes)     newshop5.jpg (30063 bytes)
Ultrasonic Cleaning


newshop8.jpg (30029 bytes)          newshop7.jpg (30021 bytes)
Repair and Assembly


SolderDesk.jpg (30090 bytes)          Shipping Bench.jpg (30043 bytes)
  Solder            Imaging            Shipping

EQUIPMENT

Shop10.jpg (30101 bytes)     Machines2.jpg (29989 bytes)     LatestShop.jpg (30140 bytes)    Machines1.jpg (30069 bytes)     Shop8.jpg (30014 bytes)

Shop12.jpg (30063 bytes)     Shop9.jpg (30054 bytes)     Shop13.jpg (30098 bytes)     newshop6.jpg (30034 bytes)     Shop2.jpg (30106 bytes)

    Shop4.jpg (30006 bytes)     Shop14.jpg (30063 bytes)     LatestShop2.jpg (30130 bytes)    

    Shop4.jpg (30006 bytes)     Shop14.jpg (30063 bytes)     LatestShop2.jpg (30130 bytes)    

shop11.jpg (32409 bytes)     shop33.jpg (30129 bytes)     Air Compresser2.jpg (29995 bytes)     Shop1.jpg (30091 bytes)


Bridgeport.jpg (29999 bytes)          shop3.jpg (39155 bytes)
Bridgeport Milling Machine
w/Anilam Digital Readout.
Repeatable  accuracy: +/- 0.0002".


OldShop7.jpg (32187 bytes)     LatheNew.jpg (30047 bytes)     Lathe3.jpg (30116 bytes)     LatheNew2.jpg (30003 bytes)     Lathe2.jpg (30068 bytes)
Hardinge HLVH Precision Tool Room Lathe
Microscope for miniature parts.
Single point thread chasing.
Repeatable accuracy: +/- .0002"


Band Saw Fence.jpg (30059 bytes)     newshop0.jpg (143486 bytes)     Band Saw2.jpg (29994 bytes)     Band Saw.jpg (29957 bytes)     Band Saw Fence R.jpg (30023 bytes)
DO-ALL Band Saw
13" Variable Speed w/Fence & Cross Slide


Vibrograf1.jpg (30490 bytes)               Vibrograf.jpg (27186 bytes)               Vibrograf2.jpg (21358 bytes)
Vibrograph B200 Watch Timing Machine

VibrografM90.jpg (30007 bytes)     Vibrografs.jpg (30062 bytes)     Vibrografs1.jpg (30137 bytes)     Vibrografs2.jpg (30127 bytes)
Vibrograph M90 Watch Timing Machine


AccutronBench3.jpg (29302 bytes)     SolderStation1.jpg (30013 bytes)     MicroMachine3.jpg (24715 bytes)     setup1.jpg (30179 bytes)                                           BulovaMicroloup.jpg (30013 bytes)
    Bausch and Lomb Stereo Zoom Microscope                                                Bulova Microloupe


ultrasonic.jpg (30047 bytes)     Ultrasonic2.jpg (122205 bytes)
GemOro Ultrasonic Cleaning Tanks


testsets.jpg (30357 bytes)     TestSets2.jpg (30437 bytes)     meter1.jpg (30098 bytes)     meter2.jpg (30149 bytes)     Accutron Test Set C.jpg (20754 bytes)     Accutron Test Set 2C.jpg (20901 bytes)
Accutron Test Meters


SolderStation1.jpg (30013 bytes)     SolderStation.jpg (30577 bytes)
Weller Digital Solder Station


AlphaFixture2.jpg (12216 bytes)     AlphaFixture1.jpg (21889 bytes)
Crystal Polishing Lathe Fixture


 Home | Accutron Repair & RestorationCustom Dials | The Workshop | 214's For SaleBands For SaleParts & Accessories 
 Accutron History  | Spaceview History  |  Photo Gallery  |  Luminous Gallery  |  Vintage Ad Gallery  |  Clock Gallery  |  Band Gallery 
 F.A.Q.Accutron ProblemsBatteriesBooklets | Message BoardFor Sale By Owner | Feedback | Contact Information |
Lost/Stolen